Maintenance method of power distribution cabinet

June 05, 2024

Daily care:

  • Regularly check whether there are signs of pests and rodents in the distribution cabinet, and take appropriate trapping measures to prevent pests and rodents from damaging electrical equipment.
  • Confirm whether all warning signs and maintenance signs are placed in the correct position, and whether emergency tools and lamps are complete and normal.
  • Check whether the cable connectors are hot and discolored, whether the grounding wires are rusted, and ensure that the cable connections are firm and not overheated.
  • Check whether the capacitor casing in the capacitor cabinet is in good condition, whether there is leakage or expansion, and whether the indicator light is in good condition.
  • Clean the inside and outside of the distribution cabinet regularly to remove dust and dirt, and maintain good ventilation and heat dissipation conditions.

First level maintenance:

  • Check whether the busbar and its lower lead are firm, whether the secondary circuit wiring is firm, and whether the fuse is intact.
  • When the air switch is disconnected without capacitor, test the action of the capacitor controller, and adjust the overvoltage protection, undercurrent protection, and switching threshold.
  • All indicator lights should be intact, check whether the controller switch position is normal, the operation should be normal, and whether the manual debugging mechanical interlocking part is reliable.
  • Check whether the fasteners of each soft starter and inverter are loose.

Secondary maintenance:

  • Check whether the drawer switch can be pushed in or out flexibly, whether its mechanical locking is reliable, and whether the contactor contacts are in good condition.
  • Check whether the elastic force of each blade in the circuit breaker is normal and whether the arc extinguishing device is intact.
  • Check whether the wiring nuts of each cable head are tightened to ensure the stability of the cable connection.
  • After disconnecting the main switches of the power receiving cabinet and the contact cabinet, check whether the secondary wiring head has good contact and is tightened without looseness.

Safety Precautions:

  • Before maintenance, the power supply must be cut off to ensure that the voltage on the power distribution cabinet has been eliminated.
  • Operators should wear anti-static clothing, insulating shoes, and insulating gloves for operation.
  • During maintenance, strictly abide by safety regulations and recommendations. If necessary, contact professionals for repairs.

power distribution panel

Need Help? Chat with us

leave a message
For any request of information or technical support, fill in the form. All fields marked with an asterisk* are required.
Submit
Looking for FAQs?
Contact us #
+86 17706919203

Our hours

Mon 11/21 - Wed 11/23: 9 AM - 8 PM
Thu 11/24: closed - Happy Thanksgiving!
Fri 11/25: 8 AM - 10 PM
Sat 11/26 - Sun 11/27: 10 AM - 9 PM
(all hours are Eastern Time)

home

products

whatsApp

Contacts Us